Smisson-Cartledge Biomedical, LLC

Smisson-Cartledge Biomedical, LLC

- Model 1200 - Rapid Infuser

0

The ThermaCor 1200 Rapid Infuser was conceived of by two surgeons at a level one trauma center.  Drs. Hugh Smisson and Richard Cartledge were on trauma call when a twelve-year-old child was brought in with major injuries from a motor vehicle accident. The child was experiencing severe internal bleeding.  The trauma staff was manually squeezing units of blood into her while trying to get their then current rapid infusion system set up.  By the time the staff could set up the system and get it operating properly, the patient had died.  The surgeons were concerned that the equipment the hospital had was inadequate; so, they investigated other infusion systems in use by major trauma centers. They determined that other facilities were using similar equipment and struggled to get their systems set up and operating quickly, thus discovering the need for a better way to rapidly infuse patients at a normothermic temperature.

Drs. Smisson and Cartledge developed their own rap...

Drs. Smisson and Cartledge developed their own rapid infuser known as the ThermaCor 1200 Infuser with two goals in mind.  First, make it quick and easy to set up and second, make it simple to operate.  Smisson-Cartledge Biomedical was formed, bringing together a team of experts to help them realize their goal.  The ThermaCor 1200 is the culmination of this team’s work to bring a faster, easier and safer rapid thermal infuser to the rapid infusion market for better patient care.

ThermaCor 1200 was born out of a belief that exist...

ThermaCor 1200 was born out of a belief that existing fluid infusion systems lacked the functionality and ease of use needed in a wide array of surgical environments. In a collaborative 10-year effort, Doctors Hugh Smisson and Richard Cartledge worked to develop a solution to this problem. The result is a portable, rugged, easy to use fluid infusion device capable of warming and infusing fluids at rapid rates and of sustaining patients in traumatic injury situations.

A REVOLUTION IN MEDICAL INFUSION SYSTEMS
The ThermaCor 1200 technology is ideally suited for use in a broad spectrum of medical procedures where heated fluid infusion is the key to successful patient outcome.

Neither microwave technology nor electromagnetic induction is utilized to heat blood while using the ThermaCor 1200. Safe and more natural dry thermal transfer technology is utilized to heat blood while using the ThermaCor 1200.

Procedures such as:

  • Hypothermia Patients
  • Resuscitation
  • Cardiac Surgery
  • Transplant Surgery
  • Irrigation
  • Urological Procedures
  • Post Surgical Care
  • Thoracic Surgery
  • Major Aortic Aneurysms
  • Plastic Surgery
  • Cancer Treatment
  • And More

Why ThermaCor 1200 Rapid Infuser

The ThermaCor 1200 is equipped with the ShurGard Vortex air trapping system.  This system captures air even when running at its maximum flow rate and only automatically purges when enough air triggers the air volume sensors helping to insure continuous flow when you need it.

The ThermaCor 1200 uses dry, conduction temperature controlled heating using a highly efficient WaveForm heat exchanger to provide you with safe fluid temperature management.

The ThermaCor 1200 was designed to be safe to use in pediatric cases.  It was designed with selectable lower fluid pressures, slower flow rates and smaller volume boluses to meet the clinical needs of the pediatric patient.

From the one-latch, fast loading cassette to the color coded snap in, quick connectors to the one button auto-prime, the ThermaCor 1200 was designed to make it simple to set up and use in less than a minute. See Video of Quick Set Up of ThermaCor 1200 Rapid Thermal Infuser

Product Specifications

COMPONENTS
ThermaCor Rapid Infuser
10 mL/hour to 1,200 mL/minute
Quick-Loading Cassette
One-Latch to engage 4 air sensors, 3 heat sensors, 3 pressure sensors and 1 cassette sensor
Patient Line – 6’
Dual Patient Line – 6’
Extension Line – 3’
3 Spike Inflow Set
Large Fluid Reservoir

OPERATING CHARACTERISTICS
Slow Infusion: 10 mL/hour to 1,200 mL/hour
Rapid Infusion: 20 mL/minute to 1,200 mL/minute
Bolus Infusion: 100, 250, 500 or 1,000 mL of fluid
Bolus Selectable Rate: 20mL/minute to 1200 mL/minute at tolerance indicated above
Recirc Mode: 300mL/min for 5 minutes
Total infusion amounts: up to 99,999 mL
Maximum infusion pressure: 100 or 300 mmHg
Nominal fluid inlet temperature: 20°C
Nominal fluid outlet temperature w/ Heater On: 37±2°C at 1,000 mL/minute
Output Temperature: Set to 40±2°C (Displays temperature in 1° increments)
Protection against air infusion: Prevents infusion of air ³50 mL at max rated flow
Time required for priming: less then 60 seconds

ENVIRONMENTAL CHARACTERISTICS
Operating Temperature: 5°C to 40°C
Relative humidity: 20% to 90%
Altitude: 0 to 10,000 feet
EMC (radiated/immunity): CISPR11 Group 1 Level B/IEC 1000-3 Level 2
Mechanical noise: <65 dBA in normal operation @ 1 meter

STORAGE AND TRANSPORTATION CHARACTERISTICS
Pump: -40°C to 70°C, 10% to 100% condensing Humidity
Cassette and Tubing: -40°C to 70°C, 10% to 100% condensing Humidity

PHYSICAL CHARACTERISTICS
Size: W8.75” x H16.5” x D13”
Weight (without Disposable): 22 lbs
IV pole mount: Accepts IV pole 0.75 to 1.5” in diameter. IV Pole should be capable of safely supporting at least 30 lb
Power Cord:
Conductor: 3-14AWG 14 x 30 strand, 9.7mm OD
Cord type/temp: SJT/105deg C
Power Rating: 1875 Watts 15A @ 125V
Hospital Grade plug

POWER SOURCE
AC Input Voltage: 1380 VA Max 100-240 VAC
Operating Frequency: 50/60Hz
Battery backup – Type

- Operating cell capacity:
Lithium ion battery pack
250 mL/hour for 2 hours
or 1,000 mL/minute for 30 minutes*
*Storage condition may affect battery characteristics

FAST, EASY SET-UP

FAST, EASY SET-UP
Sterile, quick loading, one-latch cassette
Primed and ready in less than 60 seconds

AUTOMATED AIR PURGE
Patented ShurGard Vortex Air Trap
Efficiently removes air at high flow rates
Only purges when sensors detect sufficient air is collected
Four separate air detection sensors
Fast, easy recovery from fluid out

REDUCED RISK OF HYPERVOLEMIA
One touch bolus operation
4 pre-set bolus selections:
100, 250, 500, 1000 ml
Controlled rapid bolus delivery
Auto-return to slow flow setting
Precise, safe volume control

ADVANCED SAFETY TECHNOLOGY
Continuous monitoring of 4 temp sensors, 4 air sensors and 3 pressure sensors
Clear, concise directions speed recovery from alarms
Ensures rapid return to continuous infusion

SUPER EFFICIENT HEAT EXCHANGER
Dry, conductive heat transfer
High efficiency WaveForm heat exchanger
Targeted 40ºC continuous heating at all flow rates
Safe temperature controlled management

PRESSURE CONTROLLED FLOW
Greater safety for pediatric and geriatric patients
Automatically reduces flow based on pressure selected
300 or 100 mmHg pressure limits
Facilitates connection to any catheter with reduced risk of catheter site damage

PORTABLE, BATTERY BACK-UP
Up to 2-hours reserve power
Minimum 30 minutes at maximum flow rate (1200ml/min)
Full range of flow rates from 10 ml/hr to 1200 ml/min with Bolus capability

PROVEN PERFORMANCE
Multiple clinical applications
1,000's of successful patient outcomes

Customer reviews