Radiotherapy Downloads
-
Beamscan - Model MR - Radiotherapy Machine - Brochure
The first motorized 3D water phantom suitable for clinical use in a 1.5 T MR environment. Benefit from a complete solution for commissioning and QA of MR-LINACs – from automatic beam data acquisition, processing and analysis to protocol-based documentation. Built to the highest quality and technology standards, BEAMSCAN MR is exceptionally robust, incredibly versatile and straightforward in ...
-
NBS - Navigated Brain Stimulation System for Radiotherapy - Brochure
For patients undergoing radiotherapy for brain metastases, it is important to preserve quality of life after a course of therapy. As a non-invasive method, SmartFocus® nTMS mapping is a valuable new tool for radiotherapists to accurately and reliably modify dosing to help preserve motor function and potentially the quality of life of their patients. ...
By Nexstim Plc
-
Elekta Studio - Unleash the Full Potential of Interventional Radiotherapy - Datasheet
Experience a comprehensive 3D image-guided brachytherapy ...
-
Monaco - Model HD - High Precision Radiotherapy Treatment Planning - Brochure
Monaco® HD Treatment Planning is the key to Elekta’s Precision Radiation Medicine. With Monte Carlo accuracy and simplified daily planning, featuring a new user friendly interface, Monaco® HD lets you achieve true precision radiation medicine, personalized for your ...
-
Elekta Infinity - Linear Accelerator - Brochure
Change is constant. Flexibility is vital. Elekta Infinity™ gives you the clinical freedom to treat a diverse range of patients with simple-tocomplex radiotherapy needs—so you can optimally treat a wider range of ...
-
DosimetryPRO Red - Film Digitizer - Brochure
VIDAR's DosimetryPRO® Advantage (Red) offers the radiation therapy market a specifically developed digitizer that meets the specific needs for those using popular standard film such as Carestream's Kodak EDR2 and film chemistry, as well as for those who use International Specialty Products' GAFCHROMIC EBT ...
-
Adaptiiv - Modulated Electron Bolus Software - Brochure
Our Modulated Electron Bolus (MEB) software module automates the design and fabrication of patient-specific and plan-specific modulated thickness electron bolus. Deliver modulated electron radiation therapy (MERT) dose distributions that provide superior sparing of healthy tissues and distal OARs compared to simple bolus electron plans. ...
-
Kvark - Dosimetry Measurements - Accelerator Commissioning Services - Brochure
In form of other services from the field of radiotherapy and dosimetry measurement KVARK Ltd. provides data collection of beam emitted by the accelerator, or services known as accelerator commissioning and ...
By Kvark Ltd
-
QUASAR - Multi-Purpose Body Phantom - Datasheet
Designed to fulfill treatment planning and delivery testing requirements as prescribed by the following guidelines: AAPM TG 53/66, IAEA TRS-430, TECDOC-1540/1583/1588, IEC 62083. A flexible QA tool designed to perform both dosimetric and non-dosimetric tests on radiation therapy systems, the QUASAR™ Multi-Purpose Body Phantom incorporates a wide variety of test objects in a solid acrylic ...
-
KONG-C - Model VBR M - Vertebral Body Replacement Implant Datasheet
Recognizing what usually remains hidden; The rough Ti-iT® titanium coating and the radiolucent BlackArmor® material make the KONG®-C VBR M vertebral body replacement a unique implant for the cervical spine. In particular, the KONG®-C VBR M paves the way for new perspectives and treatment approaches in tumor/radiation therapy. ...
By icotec ag
-
Elekta Versa HD - Hypo-Fractionated Radiation Therapy - Datasheet
Versa HD—our premium system—delivers absolute reliability, accuracy and confidence in stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT) treatments, to help you grow your stereotactic program as a mainstream technique. Confidently treat complex or challenging cancers with submillimeter, end-to-end ...
-
Elekta Unity - Model MR/RT - Magnetic Resonance Radiation Therapy - Brochure
It is our goal to help you deliver the best possible radiotherapy, for every patient, every time. Designed in collaboration with industry-leading experts and world-renowned cancer research institutions, Elekta Unity—our breakthrough MR-Linac technology— positions you at the forefront of patient-centric cancer ...
-
Elekta Versa HD - Hypo-fractionated Radiation Therapy System - Brochure
Hypo-fractionated radiation therapy demands the highest levels of accuracy and precision. Versa HD Series with HDRS pushes the boundaries of your stereotactic capabilities. As evidence continues to grow for new radiosurgery indications ensure you have the right platform to empower the treatments of ...
-
Vigeo - Model Biomarc IGRT - Fiducial Marker for Radiation Therapy - Datasheet
Used to target localization for lesions or organs which move in respect to external anatomy. Pure gold cylinders version specially knurled to inhibit migration. Pyrolytic carbon coated zirconium oxide bar-bell version to reduce the artifacts. Provide visualization under fluoroscopy, X-ray, CT, MRI, ultrasound and other imaging modalities. Preloaded in a pre-waxed tipped needle or in a wax- free ...
By Vigeo srl
-
Quasar - Respiratory Motion Phantom (pRESP) - Datasheet
The QUASAR™ Respiratory Motion Phantom is a programmable state-of-the-art breathing simulator for conducting quality assurance testing on radiotherapy systems. Using a personal computer to communicate with the QUASAR™ Respiratory Motion Phantom, the software application downloads patient respiratory waveforms to the phantom, simulating the breathing ...
-
Quasar - Heavy Duty Respiratory Motion Platform- Brochure
The QUASAR Heavy Duty Respiratory Motion Platform is a programmable breathing and patient motion simulator for the quality assurance of motion-guided radiation therapy systems using any large-scale phantoms up to 45 kg (100 lbs). The Platform HD’s unique multi-directional motion simulation capability enables in-line translation with both the sagittal plane in the SI direction, or at a ...
-
IZI Medical - Gold Fiducial Markers - Brochure
IZI Medical Products provides all the marking tools you need to better verify localization and reduce your number of fractions. Take our top-selling IZI Gold Fiducial Markers, which enhance accuracy and efficiency during radiation therapy. These implantable markers are used in IMRT, CRT, and IGRT treatment to provide real-time, accurate localization of the treat- ment volumes. Used in soft tissue ...
-
Quasar - Penta-Guide Phantom - Brochure
The QUASAR™ Penta-Guide Phantom is recognized globally as the preferred tool for commissioning and daily testing of Image-Guided Radiotherapy (IGRT) systems. The QUASAR™ Penta-Guide Phantom ensures the accuracy of LINAC-mounted On-Board Imaging (OBI) guidance systems, including KV, MV, and X-ray Volumetric Imaging (XVI) using Cone Beam CT (CBCT). Its simple and innovative design ...
-
IZI Medical - Multi-Modality Markers - Brochure
IZI Medical Products designed our series of Multi-Modality Markers to provide a clear and accurate reference point on any type of scan. Made of a hydrogel component with a medical grade adhesive, they appear as a bright object on CT, MRI, nuclear medicine, PET and x-Ray scans and can be seen on all MRI sequences. These versatile markers attach securely and detach easily. Our Radiology/Radiation ...