  • Effects of fluorine implantation on polysilicon with high–k Er
    2
    O
    3
    dielectrics

    This paper reports on electrical and physical characteristics of erbium oxide (Er2O3) dielectric films combined with fluorine implantation on polycrystalline silicon. It was found that high–k Er2O3 polyoxides with fluorine implantation have lower trapping rates and higher dielectric breakdown fields than as–deposited samples. Research indicates that the fluorine ion can passivate dangling and ...


    By Inderscience Publishers

  • Ultra low–temperature microwave annealing for ultra–shallow junctions and P–MOS devices

    Low energy ion implantation and low–temperature microwave annealing were used in this study to fabricate ultra–shallow junctions (USJs). A two–steps modulatory microwave annealing (MWA) process was employed to recover and activate a boron (400 eV) implanted silicon wafer. In the first step, 2.4 kW high power MWA was used to regrow an amorphous layer with the crystal silicon phase and thus enhance ...


    By Inderscience Publishers

  • Plastic neuronal probes for implantation in cortical and subcortical areas of the rat brain

    We discuss the fabrication of flexible implantable probes for recording neuronal activity in the rat brain. We fabricated such probes bearing 12 platinum electrodes, using polyimide as a substrate and SU–8 as an insulation layer. The fabrication process was simplified through the use of laser ablation to define the probe outline. The probes showed not only good mechanical flexibility but also the ...


    By Inderscience Publishers

  • Investigation of the random dopant fluctuations in 20–nm bulk MOSFETs and silicon–on–insulator FinFETs by ion implantation Monte Carlo simulation

    In this paper, we proposed a simulation approach for studying the random dopant fluctuation (RDF) effects in the nanoscale MOSFETs using only the TCAD tools. We use this approach to simulate the RDF effects in the 20–nm gate–length bulk MOSFETs, silicon–on–insulator (SOI) single–gate (SG) and triple–gate (TG) FinFETs for demonstration. This approach utilises the stochastic nature of the Monte ...


    By Inderscience Publishers

  • Medit’s Artificial Implant Supra-structure Identification System in Action

    In this presentation we detail the implant suprastructure identification system where an existing abutment is removed and scanned extra-orally to capture the margins readily after the abutment is ...


    By CAD-Ray

  • BEAR III Clinical - Case Study

    The BEAR Implant is the first medical advancement to enable your body to heal its own torn anterior cruciate ligament (ACL). That’s a big deal, because until now your ACL would have been replaced with either another tendon from your body or a tendon from a deceased donor. The BEAR Implant is different because it works with your own blood to heal the torn ends of your ACL back ...


    By Miach Orthopaedics, Inc.

  • Implant Paralleling Device

    As a professional manufacturer, LZQ have high quality implant paralleling device for sale! Just contact us! "LZQ is a high-tech joint venture in the light of China's Rejuvenation, Great Harmony, Propagating health, Joyance & Sunshine... LZQ has been accumulating over 20 years of R&D experience in export-oriented medium and high-end CNC precision cutting tool, profile fixture, brazing ...


    By LZQ Tool Co., Ltd.

  • Implant Depth Gauge

    Description Application domain: for implantology Material: Ultra high anti-rust & high-hardness stainless steel, titanium, titanium alloy, high anti-rust stainless steel LZQ is an OEM factory for all kinds of dental implant tools, such as Depth gaugeP43, Parallel Pin P37, Drill Key P47, Wrench P53, Screwdriver P79, Tap P152, Lance Drill P172,Bone Drill Point P227, Abutment P25, ect. We ...


    By LZQ Tool Co., Ltd.

  • Biomechanical Evaluation of an In Situ Cured Silicone Rubber Nucleus Replacement Device

    A new intervertebral disc nucleus replacement device having three major features has been designed, comprising: 1) a peripheral textile band, 2) a silicone membrane filled with silicone that cures in situ forming an elastomeric implant and 3) an internal chamber that allows for deformation of the cured component (Figure 1). Samples of this device were subjected to biomechanical flexibility ...

  • Part 1: In-vitro release of gentamicinpalmitate coating in uncemented titanium implants

    Microporous surfaces of commercially available uncemented Tilastan® implants were coated with gentamicinpalmitate. The roughness of the titanium implant surfaces remained largely intact. During the first few days, the gentamicin release was comparable to the elution of this antibiotic from commercially available PMMA bone cements. Compared to PMMA cements, the implants coated with the ...


    By Inderscience Publishers

  • High Energy Pelvic Trauma in a Geriatric Patient Treatment with the Curvafix IM System- Case Study

    CASE PLANNING Intention to place three CurvaFix® IM Implants: one in S1 and one in each of the left and right anterior ...


    By CurvaFix, Inc.

  • Increasing contact area of microelectrodes in implantable microchannel array system for peripheral nerve regenerative using metal deposited nanospheres

    Electromechanical guidance of neuron outgrowth is an essential route to promote nerve regeneration. The design and fabrication process of a three dimension (3D) device made as a bundle of parallel micro-channels, which can be used as a 3D regenerative implant for peripheral nerve repair, is now under investigation. The device is entirely made of highly compliant polyimide films. Metallic ...


    By Inderscience Publishers

  • Bear-Moon Clinical Case Study

    The BEAR Implant is the first medical advancement to enable your body to heal its own torn anterior cruciate ligament (ACL). That’s a big deal, because until now your ACL would have been replaced with either another tendon from your body or a tendon from a deceased donor. The BEAR Implant is different because it works with your own blood to heal the torn ends of your ACL back ...


    By Miach Orthopaedics, Inc.

  • Biomechanical Flexibility Testing of an in Situ-Cured Silicone-Based Disc Nucleus Prosthesis

    A new intervertebral disc nucleus replacement device having three major features has been designed, comprising: 1) a peripheral textile band, 2) a silicone membrane filled with silicone that cures in situ forming an elastomeric implant and 3) an internal chamber that allows for deformation of the cured component (Figure 1). Samples of this device were subjected to biomechanical flexibility ...

  • RockWorks Neural Implant Interface

    RockWare is pleased to announce the immediate availability of the “RockWorks Neural Implant Interface”. This optional add-on to RockWare’s flagship product, RockWorks, provides an alternative means for selecting options and settings from the various RockWorks programs. According to RockWare’s head of development, Dr. Ferd Burble, “Our most common technical support ...


    By RockWare, Inc.

  • Nanotechnology in biomedical applications: a review

    Incorporation of functionalised and modified nanostructures in various biomedical applications has generated considerable research interest in recent years. The applications of nanotechnology in medicine and biomedical engineering are vast and spans areas such as implant and tissue engineering, diagnosis and therapy. The present scenario demands designing of nanotools which can respond to the ...


    By Inderscience Publishers

  • Enhancing low cost stainless steel implants: bioactive silica–based sol–gel coatings with wollastonite particles

    A hybrid organic–inorganic sol–gel coating with the addition of wollastonite particles is used as a potential solution to improve performance of low cost AISI 316L stainless steel. This work is focused on characterising the coatings by studying their synthesis and deposition, electrochemical, and in vitro and in vivo response. The coated implants presented in vitro Ca/P–rich ...


    By Inderscience Publishers

  • Jerusalem firm in funding bid to test ‘micro-pancreas’ on humans

    An implantable ‘micro-pancreas’ with the ability to produce insulin in response to blood glucose levels has been created by Israeli scientists. Betalin Therapeutics has tested the technology on animals with some success and is now looking to raise enough funds to be able to put it through clinical trials. It combines cells and a biological scaffolding, which situates those cells and ...


    By Betalin Therapeutics Ltd.

  • Surgical Ratchet Wrench

    Description Application domain: Implant Material: Ultra high anti-rust & high-hardness stainless steel, titanium, titanium alloy, high anti-rust stainless steel Type: Open type, closed type LZQ is an OEM factory for all kinds of dental implant wrenches, such as, Drill Key,Parallel Pin, Wrench , Screwdriver, Tap, Lance Drill, etc. We can also produce a whole kit of tools for customers' ...


    By LZQ Tool Co., Ltd.

  • Surface properties of nano–structural silicon–doped carbon films for biomedical applications

    Hydrogenated diamond–like carbon (DLC) containing Si films were synthesised using the radio frequency plasma enhanced chemical vapour deposition. The results show that all Si–doped DLC films exhibited a similar amorphous structure as non–doped DLC films. Doping Si caused graphitisation of C and reduced the surface hardness. Moreover, the surface roughness of the films decreased with the Si ...


    By Inderscience Publishers